A roll of underlay one metre wide will not carry each new horizontal course one metre farther up a clay tile roof. The lower edge covers a strip of the course already laid. That overlap can decide whether a full additional strip is needed even when the estimator has measured the slope accurately.
Consider a rectangular roof plane with a hypothetical 7.2 m run measured up the slope. Take a 1 m roll width and ignore ridge and eave allowances for the moment. With a 100 mm overlap the first strip spans 1 m and seven more add 6.3 m, for 7.3 m in eight strips. With a 150 mm overlap those same eight strips reach only 6.95 m. The shortfall is 250 mm along the slope, but the extra course has to extend across the full width of that roof plane.
Locate the seam on the section
The UK Roof Tile Association illustrates why the two overlap figures can both appear on a detail sheet. In its rafter-and-batten guidance for pitches above 15 degrees, it gives different minimum unsealed headlaps for supported and unsupported seams. A sealed joint depends on the particular underlay and sealing system. Have the designer identify the applicable detail before using either width in the estimate.
Calculate the actual slope length including the specified terminations, then lay out the strips. For each strip, add the length lost at any splice across the roof and check how many continuous lengths the rolls will supply. Keep the tile exposure out of this arithmetic. It belongs to the covering above and does not determine how much underlay arrives on the pallet. The Tile Roofing USA underlayment guide provides more background on this layer.