Should the replacement hood on a tiled roof have a bird screen?

Trace a laundry exhaust to its outlet before the roofer orders a stock screened hood for a clay tile replacement.

By the Slate, Tile & Metal Guild ·

A clay tile reroof includes a new hood for each small duct on the rear slope. The proposed finish matches the existing clay and all three hoods come with mesh across the opening. Before approving a set, ask the mechanical contractor what discharges through each one. The laundry outlet has a requirement that a photograph of the old cap cannot settle.

For example, section 504.4 of the 2025 Mechanical Code of New York State calls for a clothes dryer exhaust duct to discharge outdoors through a backdraft damper. It prohibits a screen at the termination. The damper is a moving closure. Fixed mesh across the air path can collect lint. A product photo showing a neat hood gives the reviewer no way to tell what sits behind its lip.

Review the cap and the roof detail together

Give the duct and its outlet the same identifier on the plan. Request the proposed terminal’s drawing showing the damper and discharge opening, together with its intended appliance use. Have the mechanical contractor confirm suitability under the project rules. Ask the tile roofer for the flashing detail for the actual profile and pitch. A cap can meet the appliance requirement while its base still needs a different flashing arrangement for a curved clay tile.

If a supplier offers one screened fitting for the bath and laundry outlets, return the schedule for separate selections. Have the installer identify each finished outlet on the owner’s elevation photograph and explain how the laundry termination can be serviced. The roof outlet identification guide helps trace an unidentified opening before any equipment is ordered.

Further reading

New York State Department of State · 2025 Mechanical Code of New York State, section 504.4. Section 504.4 is a New York mechanical-code example. Confirm the applicable code and dryer instructions for the actual installation.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.