An architect requests the global warming potential of a tonne of concrete roof tile at the factory gate. Two entries in a supplier’s environmental product declaration catch the estimator’s eye. One is positive and the other negative. Adding the pair produces a lower number, but it also changes the period the answer covers.
Benders Deutschland’s 2026 declaration for Palema S-Stein and Mecklenburger tiles gives a worked reference. In the row for total global warming potential, the combined production stages A1–A3 are 145 kg of carbon dioxide equivalent per 1,000 kg of tile. The use stage B1 is −60 kg on the same basis. The manufacturer models carbonation, a reaction in which concrete exposed to air takes up some carbon dioxide, and assumes a 50-year reference service life.
Fill the column the architect requested
For those tiles, enter 145 in a column headed “A1–A3, kg CO₂e per tonne.” Enter −60 separately if the project model includes B1. Subtracting 60 gives 85, but that number includes a modeled future event. It also leaves out delivery, installation and end-of-life stages. An annual credit of 60 would introduce a different error by counting the published use-stage result repeatedly.
Keep the declaration number, product range, plant, unit and indicator beside the worksheet row. If the project reports per square metre, apply the documented tile mass for the specified coverage when converting units. The Guild’s worked example of unit conversion shows how to keep that calculation visible. A supplier proposing a different plant or product should identify the declaration that represents it before anyone carries the uptake figure forward.