A quote for de-icing an entrance might specify the cable, controller and number of clips but describe the roof simply as “pitched.” That leaves out a detail that can change the whole job. A clip listed for the chosen heating system may use an attachment method the manufacturer excludes on a tiled eave.
In its WinterGard Wet design guide, Chemelex lists attachments by roofing material. The note beneath Table 3 explicitly rules out adhesives on slate and tile roofs and directs readers to the roofing manufacturer or a Chemelex representative for the recommended method. A compatible adhesive in the same guide does not override that roof-specific restriction.
Trace the proposed route on the bid drawing
Mark where the cable runs on concrete tile, where it reaches the gutter and which downspout takes the water. Ask the contractor to identify the attachment for each location. If the price includes glued clips on the tiles, ask for the manufacturer-supported alternative and its cost before authorizing work. Substituting a screw in the field leaves the question of how the particular roof can be secured and kept weathertight unresolved.
State what the owner wants at the entrance. This system is intended to keep a route open for meltwater. If the concern is a mass of snow sliding from the pitch above the door, that requires a separate assessment. The snow-retention layout example for a tiled roof shows what a designer may need from the roof survey.