A purchasing team finds a second flat concrete tile of the same length. It covers a little more width per piece, so fewer pieces are needed. Before carrying the fastening schedule over to the revised order, find the tile dimensions on which the original schedule was based.
Appendix A of the Florida high-wind tile manual illustrates this change on a single building. Its first example uses a 17-inch tile with an exposed width of 11.07 inches. The next keeps the length and changes the exposed width to 12 inches. Width enters the calculation of the wind’s turning effect on each tile. Under otherwise identical assumptions, the width term alone increases by about eight percent. Reducing the number of tiles on the purchase order does nothing to reduce that effect on an individual tile.
Mark the dimension between repeats
Ask the supplier to identify the installed cover width on the product drawing. An overall measurement across a loose tile can include a sidelap that its neighbor covers. Give the designer the original and proposed cover widths, total lengths, profile and unit weights. Mark which roof zones the original attachment detail served. If the substitute also changes how the tile bears or how it attaches, include that drawing alongside the dimensions.
Ask for a written determination on the proposed product and assembly before releasing the order. The eight-percent illustration concerns one term under fixed assumptions. It cannot specify a fastener count or establish that the original attachment has capacity to spare. If the two submittals also express wind speed differently, the Guild’s guide to wind-speed labels identifies another input to reconcile.