Two proposals for a concrete tile reroof can both say “radiant barrier” while putting the reflective surface on opposite sides of the deck. That matters when one bid leaves most of the deck in place or the insulation contractor intends to fill the space next to the sheathing.
Take an attic-facing product first. LP’s TechShield panel has foil bonded to the sheathing. Its roof detail turns the foil down toward the framing and shows at least three-quarters of an inch of air space. The space between the concrete tile and the top of the deck is on the other side of the wood. Measuring that space tells the owner nothing about what faces this foil.
An above-deck foil has a different section. In its installation guidance for tile roofs, RoofingFoil calls for at least half an inch of air facing the reflective surface. A detail that puts another sheet directly over that surface needs another look, even if the tiles themselves sit on battens farther up.
Put both bids on the same roof section
Have each bidder mark the concrete tile, water-shedding underlayment, deck and insulation. Circle the foil face, then draw a short arrow to the first material opposite it. Ask for the product detail that supports the distance between those two surfaces. If the quote supplies new foil-faced panels only where damaged decking is replaced, have the estimator mark that area separately. The total tile area on the bid could be several times larger than the area receiving new panels.