Preserving the craft. Building its future.

Concrete tile · Ventilation

Will a concrete tile reroof leave enough vent area for the whole-house fan?

Translate a fan’s airflow into a net free vent area and check which outlets actually serve its attic.

By the Slate, Tile & Metal Guild ·

Before a tile crew removes old roof vents, find out whether a whole-house fan discharges into the attic. The owner may call it an attic fan because its motor is overhead. Ask for the model and the airflow path: does it draw from the living area and discharge into the attic? That answer changes what the new roof vent schedule must account for.

QuietCool’s Classic whole-house fan guide recommends one square foot of net free venting for each 750 cubic feet per minute of fan airflow. For an illustrative system delivering 3,000 CFM, that recommendation works out to four square feet, or 576 square inches. Use the guide for the actual fan when preparing a project schedule. The example is a fan-specific performance check and does not establish the building’s code ventilation requirement.

Check where the outlets open

Mark the attic space receiving the fan discharge on a roof plan. List the usable vent openings serving that space and the net free area for each exact vent model. A tile-shaped vent on a detached garage contributes nothing to the house attic. Nor does a grille in the right roof slope establish an open air path if the framed bay beneath it is isolated. Have the roofing and mechanical teams resolve any uncertain connection before covering the opening.

For example, if the verified schedule totals 450 square inches against that illustrative 576-square-inch target, the unresolved difference is 126 square inches. Give that figure to the designer. An extra vent’s external footprint cannot tell you how much of the difference it closes. At handover, record the actual vent models and locations against the fan model. The Guild describes how vent profile affects the net-area entry.

Further reading

QuietCool · Classic whole-house fan owner’s guide, system venting recommendation. The cited source provides the technical basis for the planning example above.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.

← All roofing articles