On an old roof, a dark sheet may cross several courses while the slate tails still show below it. The Society for the Protection of Ancient Buildings records a mid-twentieth-century treatment called turnerising. Workers spread mesh and bitumen across the outer face of a failing slate covering. This differs from lime-mortar torching, which a surveyor encounters on the underside. The distinction matters when the owner asks how many individual slates can go back.
Draw the edge of the covering first
Mark where the surface treatment begins and ends on each slope. Record what supports the identification, such as exposed mesh crossing visible slate joints at an existing break. Where a photograph shows only a black surface, describe what is visible and leave the material identification provisional.
Suppose three courses remain visible below a coated area. They can establish a local exposure and show how the uncovered eave looks. Their edges cannot tell a bidder whether the slates farther up can be separated intact. Carry the coated area into the estimate as an area awaiting investigation. Ask the conservation team to agree where an authorized opening would answer the question and how that opening will be made weatherproof.
After opening, record the pieces that separated intact, the pieces damaged during separation and the extent still concealed. Those observations let the owner revise a salvage allowance without converting every dark square foot into a promised stack of reusable slate.