A roofing slate arrives with a triangular chip at one bottom corner. The receiver measures across the diagonal break. The specification refers to loss in either direction. The two measurements answer different questions.
For rectangular slates with a broken corner at the exposed end, the Slate Roofing Contractors Association’s guidelines give a rejection threshold of more than 1½ inches in either direction. Use the intact portions of the side and butt edges to locate where the original corner would have been. Record how far the loss extends along each edge. In a hypothetical delivery, a chip running 1¾ inches along the butt and ½ inch up the side exceeds that criterion along the butt. Averaging the two dimensions would conceal the reason for rejection.
Give a possible recut its own size
The association allows consideration of damaged slates for cutting into smaller sound pieces. The receiving record can therefore distinguish a rejected full-size piece from a candidate for a particular smaller size. Have the slater check that the intended cut yields sound stone with suitable hole and edge positions. Record the finished size and acceptance before crediting it to the smaller-size order.
Check which guidelines and appearance criteria the project actually adopted. A deliberately clipped decorative corner belongs against its approved pattern. A crack extending into an otherwise small corner chip needs its own assessment. Neither condition can be settled by the two edge measurements alone.