A bid form has one box for the number of freeze-thaw cycles a roofing slate passed. The supplier sends a signed declaration with no cycle count. Before entering zero or asking the supplier to repeat a test, compare the question on the form with the information the producer actually declared.
Read the two entries together
Welsh Slate’s January 2025 declaration for Cwt-y-Bugail Celtic grade names EN 12326-1:2014. In the durability section the producer reports its A1 water-absorption classification, with an upper bound of 0.6 percent. On the next line it records freeze-thaw cycling as “Not required.” The sheet gives neither an exact measured absorption percentage nor a number of completed cycles. Its directional strength values elsewhere on the page are not identified as results after freeze-thaw exposure.
On a comparison sheet, preserve those distinctions. Enter the absorption class and its limit in the absorption column. In the cycle column enter the producer’s stated disposition and cite the declaration by product, reference and date. If a spreadsheet accepts only numbers, leave the numeric cell empty and add a visible note explaining why. A zero can be mistaken for a measured result and then carried into a scoring formula.
Match the response to the specification
Go back to the actual project requirement. A request for the manufacturer’s declared performance can be answered with the applicable declaration. A request for measured strength after a named conditioning procedure asks for different evidence. In the latter case, send the exact clause to the supplier and ask the specifier to resolve any difference before ranking bids. Keep the response with the comparison so the next reviewer can reconstruct the decision.
When checking that the document belongs to the slate offered, the Guild’s guide to matching the quarry product and declaration explains which identifiers to compare.