The architect approves a sandfaced clay tile in place of a smooth finish. The ridge line is still the same length, and the ridge caps are the same colour. A buyer comparing only dimensions could reasonably leave the ridge kit on the original order. The field tile’s surface is the detail that needs another look.
Wienerberger’s installation guide for Sandtoft RollRidge lists broad compatibility with clay and concrete tile, then specifically excludes tiles with a sanded finish. It points readers toward a profile dry ridge system for that situation. A ridge cap that looks right on the sample board therefore settles only part of the substitution.
Reopen the accessory line before dispatch
Suppose a merchant has already reserved the ridge rolls for the smooth-tile specification. Send the approved tile’s manufacturer, profile, exact finish name and a copy of its data sheet to the ridge supplier. Ask for written identification of a compatible system, including the components that go under and between the caps. Check whether the change affects the ventilation provision assumed in the roof design. A generic request for a matching red ridge can come back with the correct visible colour and the original unsuitable roll.
Revise the ridge order with the confirmed component references and release or reassign the old stock. Keep a copy with the approved field tile sample record. On delivery, the foreman can compare the kit label against that revision before it is taken onto the roof.