Water shows up below a cupola only when rain comes from one side of the building. A roofer proposes opening the surrounding slate, while the louver supplier sends a sheet headed “water penetration.” Before authorizing either repair or replacement, ask everyone to mark the opening and the first observed wet surface on the same drawing.
Read the heading above the result
AMCA describes two different ways of evaluating a louver. The basic water-penetration test draws air through the blades while applying water. Its result can identify the intake velocity at which water starts to pass the test specimen. The wind-driven-rain test adds an external wind and rain exposure and measures how much water the louver rejects under the stated conditions. A velocity from the first test supplies no wind-driven-rain classification.
Ask the supplier to identify the actual model, the test named on its sheet, the reported airflow and any drainage accessory included in the test. Record which face of the cupola was exposed during the event, whether a fan was running if one serves the opening, and where water appeared relative to the sill and roof flashing. The rain observation guide can help keep weather readings tied to their location.
A water trail beginning behind a louver gives the investigator a specific opening to examine. Moisture first seen below the flashing calls for tracing that junction as well. Neither observation alone identifies where water entered. Keep any proposed slate removal tied to the remaining question and have the project professional specify the next inspection.