A slate repair estimate calls for replacing a small area of damaged boarding with “32/16 rated sheathing.” The carpenter has named a panel rating. The roofer still needs to know where the patch ends, how thick it will be and what the new slate fasteners will enter.
On APA Rated Sheathing, the first number gives the maximum recommended spacing of roof supports, measured in inches from center to center. The second gives the corresponding spacing for use as a subfloor. For a panel marked 32/16, those spacings are 32 inches and 16 inches respectively. Thickness appears elsewhere on the stamp. APA bases the span rating on the panel’s long dimension or strength axis crossing at least three supports.
Draw the patch as it will be cut
Suppose the repair sketch shows a narrow strip from one rafter to the next. Even if those rafters are only 16 inches apart, the sketch shows two supports. Simply comparing 16 with 32 misses the difference between that strip and the arrangement behind the rating. Ask the designer to show the supported edges, blocking where required and panel orientation for the actual opening.
Have the carpenter and slater review the same section. Record the existing board thickness and edge profile, the proposed panel grade and thickness, the finished deck level at the joint, and the specified slate attachment on either side. A useful bid identifies who will resolve an unexpected board thickness or a patch boundary that falls between rafters before the roof is covered.