Preserving the craft. Building its future.

Slate roof maintenance · Leak investigation

A ceiling stain below a slate wing appears after the roof hydrant is shut off

Trace the hydrant’s drain and the adjacent roof flashing before assigning a dry-weather leak to the slater.

By the Slate, Tile & Metal Guild ·

A service roof below a slate wing can have a water supply for washing windows or maintaining equipment. If a stain on the ceiling grows after someone uses the hydrant on a clear day, record when the water was turned off. On some models, closing the handle starts a second flow of water inside the building.

Find the model before following the pipe

Woodford’s RHY2 releases water from its valve body into a separately piped drain when the hydrant shuts off. Its SRH sanitary model uses an internal reservoir and has no separate drain line. A plumber looking for a missing pipe needs the model identification first. Ask facilities for the fixture schedule and the last service ticket. Put the hydrant, its supply, any identified drain destination and the stained ceiling on the same section through the building. Use a dashed line wherever the pipe disappears from view.

Give the plumber and the slater the same timeline

For the next reported incident, record whether it rained, whether a hose discharged onto the roof, the approximate shutoff time and where water first appeared indoors. Water used to wash the windows can also reach the roof-to-wall junction. A dry day narrows the inquiry without settling which path the water took. The plumber can assess the drain arrangement under controlled conditions. The slater can inspect the adjacent courses and flashing against the location where water actually reached the roof.

Close the ticket with the specific path observed and who verified it. If the investigation reveals a separate defect in the slate, locate that finding independently in the slate inspection report. This gives the owner a reason for each repair and a way to tell whether it worked.

Further reading

Woodford Manufacturing Company — Commercial Roof Hydrants, model-specific drain arrangements. Woodford describes its own hydrants. The investigation below concerns an existing hydrant on a service roof next to a slate slope.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.