Preserving the craft. Building its future.

Tile roofing · Energy documentation

Which solar roof tiles count toward California’s active-PV exemption?

Use the active-module layout to separate generating area from matching filler on a steep-slope reroof.

By the Slate, Tile & Metal Guild ·

On an integrated solar roof, an inactive filler tile can match its generating neighbor closely enough that a finish photograph reveals no boundary. That matters when a permit reviewer asks which roof area qualifies for the active photovoltaic exemption. A rendering and a single product-family name leave the reviewer guessing.

Example 9-18 in the California Energy Commission’s 2025 single-family manual addresses a full steep-slope roof replacement in climate zone 12 under the prescriptive compliance approach. The commission limits the exemption to the active photovoltaic area. The remaining roofing in that example must meet the applicable cool-roof requirements and carry a Cool Roof Rating Council rating.

Reconcile the drawing with the product schedule

Suppose a drawing shows 900 square feet of integrated roofing. The manufacturer’s layout identifies 560 square feet as active and the remaining 340 as inactive filler. On that hypothetical drawing, claim 560 square feet under the active-PV exemption. Give the reviewer the product identification and rating for the 340 square feet of filler. Schedule any conventional tile on the rest of the roof separately.

Ask for a revised area breakdown if the installer moves the array or substitutes a matching filler. Save the dated layout beside the rating record. The solar module order count answers a different question: it tells purchasing how many pieces to obtain. Spare modules in the delivery cannot add generating area to the roof drawing.

Further reading

California Energy Commission — 2025 Single-Family Residential Compliance Manual, chapter 9, example 9-18. Example 9-18 concerns prescriptive compliance for a full steep-slope replacement in California climate zone 12. Check the requirements applicable to the actual project.

Published by the Guild as part of Tim Kelly’s Slate Boss resource network. These educational guides support project conversations and do not replace an on-site inspection or a project specification.