A concrete tile reroof estimate includes a ventilated ridge and says the existing powered attic fan will stay. On paper the owner appears to be getting two ways to exhaust hot air. The question to ask is where the fan will get replacement air while it runs.
GAF’s attic ventilation bulletin describes the risk of combining exhaust systems serving the same space. A powered fan can draw air in through a nearby ridge opening. Air then travels a short route across the upper attic, bypassing part of the path from soffit to ridge that the designer intended. Adding the rated openings together cannot tell the owner which way air will move.
Trace each opening to a particular attic
Start with a section through the fan, ridge and eave. Identify any wall that divides the attic, any blocked intake, and whether the proposed tile ridge ventilates the attic itself or only the space beneath the tiles. A visible opening below a ridge cap does not settle that last question. Ask for the section through the roof deck and underlayment as well as the tile fitting.
Give the designer two conditions to review: fan running and fan off. If openings serve different compartments, mark those boundaries. If they share an attic, ask for one coordinated ventilation scheme and a clear scope for the fan, wiring, old roof opening and new ridge. Confirm who will close any redundant opening before the field tiles go back. The tile vent area guide helps with component sizing once the air path has been established.