A concrete tile reroof gives an owner a chance to replace an aging domestic hot-water collector while it is off the roof. The replacement fits the available space and carries an OG-100 number. Can the owner file that number against the original system certificate and release the order?
Start with the two equipment records. Under ICC-SRCC’s programs, OG-100 covers the solar thermal collector. OG-300 covers a complete solar water heating system. A collector may appear in more than one system configuration. Its own certificate cannot identify which tank or collector quantity went into a particular installation.
Trace one real parts list
On system certificate 30004364, the collector line identifies one SunEarth TRB-20 and OG-100 number 10002146. Other lines identify the solar tank, drainback tank and auxiliary heater. These entries give a facilities manager two places to look for evidence. The contractor can record the equipment being lifted outside, while the owner supplies the indoor equipment labels and the original system paperwork. An invoice that says only “solar panel removal” identifies neither assembly.
Put the decision before the tile goes back
For a lift and return, label each collector position on the roof plan and record its model. For a substitution, put the proposed model and quantity alongside the existing ones. Ask the system provider to identify the documentation covering the proposed combination. Until that question is resolved, carry the replacement as an open item in the reroof scope. A matching frame size may help the roofer plan the work without answering the equipment question.
Keep a second sign-off for the roof itself. Identify who details supports and weathering where services cross the new tile, who reinstalls the collectors and who checks the operating system. File the resulting equipment schedule with the roof handover records so the next owner can trace both the water heater and the roof work.