After a concrete tile roof is relaid, the crew reconnects the downpipe to a garden tank. From the ladder, the leaf basket looks intact. Across the yard, an overflow pipe still carries water away when the tank fills. An owner doing the handover needs to see what keeps insects out at that second opening as well.
NSW Health recommends closely fitted insect screens at tank inlets and overflows, with regular inspection for damage or gaps. Water normally leaves through the overflow, but the opening can also give mosquitoes access to stored water. A coarse leaf catcher on the downpipe serves a different purpose. Photographing that basket alone leaves the overflow unchecked.
Follow the paths on a sketch
Draw the downpipe that was disconnected for the tile work and trace it to the tank inlet. Mark the overflow fitting separately and follow its pipe to the discharge point. Ask the tank installer where insect exclusion is provided on each path and how the owner can inspect it. If a fitting is concealed, record its access location and product information instead of guessing from the shape of the outlet.
At handover, have the responsible contractor confirm that the screens are intact and seated around their edges, and that the overflow remains able to discharge. A solid plug would close the opening while defeating its purpose. Keep the two opening labels with the reconnection date and identify who will inspect them thereafter. Record the first-flush device separately if one is fitted. Screening addresses insect access. Any decision to use the water for drinking needs its own water-quality assessment.
